Search ILC

Products

The LightLEEDer-EVO is a distributed lighting control panel that simplifies installation. This panel operates the R20 style relays that connect using a standard CAT-5 cable. The LL-EVO has 16 pre-programmed lighting applications, push to connect terminals with color coded labels, internal time clock, and galvanically isolated 0-10V dimming. The LL-EVO can operate as a stand-alone panel or networked, reverting to stand-alone automatically if the network is interrupted. When installing, simply set the panel for a lighting application and it is up and running. This allows the installer to confirm wiring and fixture performance from the start saving time and start-up expense. Each of the 16 application programs can still be modified or customized using the standard ILC software. The remote mounted R20D relay has both line voltage and the 0-10V dimming control wire leads for easy wiring.

  • 16 Pre-configured lighting applications
  • Full LightLEEDer panel capability
  • Integrated time clock
  • Stand-alone or Network operation
  • CAT-5 connections for 4 remote dimming relays
  • Galvanically isolated 0-10V dimming
  • Inputs for 2 daylight sensors
  • Powered inputs for occupancy or vacancy sensors
  • Made in USA
Lighting Applications and CAD

Applications F0 to FF LL-EVO Combined CAD Drawing

LL-EVO Application Control Mapping Matrix

Application F0 LL-EVO 2-Room, 1-Zone, 1-Daylight Zone CAD Drawing

Application F0 LL-EVO 2-Room, 1-Zone, 1-Daylight Zone PDF Drawing

Application F1 LL-EVO 1-Room, 2-Zone, 1-Daylight Zone CAD Drawing

Application F1 LL-EVO 1-Room, 2-Zone, 1-Daylight Zone PDF Drawing

Application F1 LL-EVO 1-Room, 3-Zone, 1-Daylight Zone CAD Drawing

Application F1 LL-EVO 1-Room, 3-Zone, 1-Daylight Zone PDF Drawing

Application F1 LL-EVO 1-Room, 4-Zone, 1-Daylight Zone CAD Drawing

Application F1 LL-EVO 1-Room, 4-Zone, 1-Daylight Zone PDF Drawing

Application F2 LL-EVO 1-Room, 2-Zone, 2-Daylight Zone CAD Drawing

Application F2 LL-EVO 1-Room, 2-Zone, 2-Daylight Zone PDF Drawing

Application F2 LL-EVO 1-Room, 3-Zone, 2-Daylight Zone CAD Drawing

Application F2 LL-EVO 1-Room, 3-Zone, 2-Daylight Zone PDF Drawing

Application F2 LL-EVO 1-Room, 4-Zone, 2-Daylight Zone CAD Drawing

Application F2 LL-EVO 1-Room, 4-Zone, 2-Daylight Zone PDF Drawing

Application F3 LL-EVO 2-Room, 2-Zone, 1-Daylight Zone CAD Drawing

Application F3 LL-EVO 2-Room, 2-Zone, 1-Daylight Zone PDF Drawing

Application F4 LL-EVO 2-Room, 2-Zone, 2-Daylight Zone CAD Drawing

Application F4 LL-EVO 2-Room, 2-Zone, 2-Daylight Zone PDF Drawing

Application F5 LL-EVO 2-Room, 1 or 3-Zone, 1-Daylight Zone CAD Drawing

Application F5 LL-EVO 2-Room, 1 or 3-Zone, 1-Daylight Zone PDF Drawing

Application F6 LL-EVO 2-Room, 1 or 3-Zone, 2-Daylight Zone CAD Drawing

Application F6 LL-EVO 2-Room, 1 or 3-Zone, 2-Daylight Zone PDF Drawing

Application F7 LL-EVO 4-Room, 1-Zone, Occupancy CAD Drawing

Application F7 LL-EVO 4-Room, 1-Zone, Occupancy PDF Drawing

Application F7 LL-EVO 4-Room, 1-Zone, Vacancy CAD Drawing

Application F7 LL-EVO 4-Room, 1-Zone, Vacancy PDF Drawing

Application F8 LL-EVO 4-Room, 1-Zone, Vacancy CAD Drawing

Application F8 LL-EVO 4-Room, 1-Zone, Vacancy PDF Drawing

Application F9 LL-EVO 1-Room, 4-Zone, Occupancy-Driven-Dimming CAD Drawing

Application F9 LL-EVO 1-Room, 4-Zone, Occupancy-Driven-Dimming PDF Drawing

Application FA LL-EVO 1-Classroom, 4-Zone, 1-Daylight_zone_a-b-c-d CAD Drawing

Application FA LL-EVO 1-Classroom, 4-Zone, 1-Daylight_zone_a-b-c-d PDF Drawing

Application FB LL-EVO 1-Classroom, 4-Zone, 1-Daylight_zone_a-b-ac-bd CAD Drawing

Application FB LL-EVO 1-Classroom, 4-Zone, 1-Daylight_zone_a-b-ac-bd PDF Drawing

Application FC LL-EVO 1 Conference-Room, 4-Zone, 1-Daylight Zone, MZD4, 5-Presets CAD Drawing

Application FC LL-EVO 1 Conference-Room, 4-Zone, 1-Daylight Zone, MZD4, 5-Presets PDF Drawing

Application FD LL-EVO Sweep Off Timer, 4-Zone, 1-Daylight Zone, MZD4 CAD Drawing

Application FD LL-EVO Sweep Off Timer, 4-Zone, 1-Daylight Zone, MZD4 PDF Drawing

Application FE LL-EVO Open Timer On-Closed Occupancy, 4-Zone, 1-Daylight Zone, MZD4 CAD Drawing

Application FE LL-EVO Open Timer On-Closed Occupancy, 4-Zone, 1-Daylight Zone, MZD4 PDF Drawing

Application FF LL-EVO 1-Room, 4-Zone, 1-Daylight Zone, Occupancy Priority On CAD Drawing

Application FF LL-EVO 1-Room, 4-Zone, 1-Daylight Zone, Occupancy Priority On PDF Drawing

Features
  • Distributed lighting controller
  • Outputs for up to 4 R20 relays
  • Remotemounted relay for direct connection to loads
  • Galvanically Isolated 0-10 dimming for 4 zones
  • Status LED and Override buttons for remote relay control
  • Standalone or networked with any LightLEEDer controller
  • Time clock includes 7/365-day calendar, Daylight Savings Time, Astronomic, Open/Close
  • 200mA power provided for occupancy or vacancy sensors inputs
  • RJ45 connectors for networking, CAT-5 devices, and R20 relays
  • ALL ILC CAT-5(LightSync) devices supported
  • Enclosure, suitable for plenum mounting
Physical

Specifications

Safeguards:

  • Power surge and spike suppression up to 123 volts on the 20VAC power input to controller
  • Memory retention for firmware and programming up to 200 years and electrostatic discharge to 4kv
  • Real time clock retention 45 days or greater without power
  • Galvanically isolation to 1500V for the 0-10VDC dimmer outputs, with revert to 100% on power loss

Physical:

  • Enclosure: 9-3/4¨x 6¨x 3¨ NEMA 1
  • Galvanized steel enclosure and screw cover
  • Provided with pre-drilled mounting holes
  • High voltage barrier separates Class 2 wiring
  • 1/2¨ nipple for mounting to electrical box
  • 6¨ wire leads for high voltage connections
  • Push to connect low voltage terminals
  • Color coded labels for easy terminal identification
  • RJ45 connectors provide for easy connection
  • Enclosure, suitable for plenum mounting

Integrated Interfaces:

  • 4 inputs for hardwire switches or occupancy sensors
  • Photocell controller for 2 sensor heads or zones
  • RJ-45 port for up to 8 ILC CAT-5 devices
  • 4 RJ-45 ports for R20 remote relays

Electrical:

  • 120/277VAC @.6 amps (120/347VAC Optional)
  • Input: 24 VDC @ 200mA maximum draw
  • Dimming: 100mA sink

Operating Environment:

  • Location: Interior space
  • Operating Temperature: 0° to 50° C
  • Humidity: 10% - 90% Non-condensing
  • Atmosphere: Non-explosive/corrosive
  • Vibration: Stationary

Certifications and Approvals: (Pending)

  • UL and CUL listed
  • FCC Part 15
  • Title 24
  • ASHRAE compliant
  • IECC compliant