The Reliant40 relay is designed for durability, flexibility, and ease of use. This relay is a superior relay that employs 4 latching nickel-silver contacts. The relay is available in 1, 2, or 3 pole configurations for controlling 120 VAC to 480 VAC loads. It is UL and C-UL listed and is rated for 120 VAC to 347 VAC per pole with current rating of up to 40 Amps. This relay carries a high fault SCCR rating of 18,000 Amps @ 347 VAC. It also features a manual toggle switch for ON/OFF activation and a Lock-ON/OFF switch to disable control from the panel electronics. Installation is easy with 1 screw and 1 push-on ribbon connector.

  • Rated for 40 Amps
  • Made in the USA
  • 4 contact latching design
  • SCCR rated to 18,000 Symmetrical Amps
  • 1, 2, or 3 pole configuration
  • Manual ON/OFF lever with indicator
  • Lock ON/OFF switch
Features
  • Made in the USA.
  • Suitable for controlling all lighting loads.
  • Electronic ballast high current inrush load rating.
  • Relay contacts consist of 4 nickel-silver contacts designed for high currents.
  • Latching relay holds position without the presence of power, saving energy.
  • Relay configurations available in 1, 2, or 3 pole ganged assemblies.
  • Manual lever override switch with highly visible indicator.
  • Lock-ON/Lock-OFF feature disables ON or OFF control from the electronics.
  • Terminals consist of 2 line and 2 load connections.
  • Screw-actuated wire clamps for use with 10-12 AWG solid or 8-12 AWG stranded copper wire.
  • Mounting is as easy as interfacing a tab and securing with a screw.
  • Operates in any position.
  • Wire strip guide located on the side of the relay.
Physical

Specifications

Physical:

  • .99¨ Wide x 2.0¨ High x 4.75¨ Long (1 pole)
  • Accepts 8-12 AWG stranded Cu wire or 10-12 AWG Solid Cu wire
  • Easy installation into any panel
  • Removable ribbon connector interface
  • Clearly marked connection designations

Low Voltage Control:

  • 18 to 24 VDC
  • Momentary duty rating
  • 50 milliseconds minimum activation time
  • 50 to 55 Ohm coil resistance
  • 100mA @ 5 VDC status & disable contacts

Electrical:

  • 120, 277 or 347 VAC per pole (controls 208/240/480 loads)
  • 40 Amps HID and ballast loads
  • 40 Amp resistive loads
  • 16 Amp electronic ballast loads (UL´s limit)
  • 1.5 Hp @120VAC motor loads
  • 18,000 Symmetrical Amp SCCR @347 VAC

Operating Environment:

  • Location: Interior Space
  • Operating Temperature: 0° to 60° C
  • Humidity: 10% to 90% Non-condensing
  • Atmosphere: Non-explosive/corrosive
  • Vibration: Stationary

Certifications:

  • CUL Listed
  • UL listed
  • FCC
Accessories
Related Downloadable Documents