The LightSync Occupancy Sensor Input module is designed to power and receive signals from 2 sensors on each of its 4 independent inputs. Eliminate expensive power packs by simply direct- wiring the sensors into the LightLEEDer inputs. This module mounts directly in the panel on the output module, or can be mounted remotely in a location central to the sensors. Each independent input can control any relay(s), group(s), or preset(s) throughout the network. Inputs also have a time-of-day or open/close time-of-action which could disable the input or change the relays controlled.

  • Provides power and inputs for occupancy sensors
  • Installs directly onto output board or remotely
  • 4 inputs per module that accept 24V signals
  • Optically isolated inputs protect electronics
  • Connect multiple sensors to each input
  • Eliminates need for expensive power packs
  • Works with major manufacturers´ sensors
Lighting Applications and CAD
Accessories
Features

General Information

  • Provides power and inputs for occupancy sensors
  • Made in the USA
  • Installs directly onto the output board
  • Digitally addressable device for a unique address
  • Remote mounting option for LightSync network
  • RJ45 connectors for remote mounting module
  • Connectors are easy non-screw push-to-connect type
  • Optically isolated inputs to protect the electronics
  • Sensor signals accepted directly on module
  • Connect multiple sensors to each input
  • Power packs not required
  • Works with most major manufactured sensors

Remote Mounting Option

  • Remote mount anywhere on the LightSync network
  • Powered from a 24VAC transformer
  • RJ45 connectors provided for easy connection
  • Mounting plate available
  • Great choice for centrally locating the module with sensors
Physical

Specifications

Safeguards:

  • Optically isolated inputs protect electronics

Physical:

  • 2.75¨ Wide X 3.5¨ High
  • Easy non-screw push-to-connect connectors
  • Digital addressing switches
  • RJ45 connectors for remote mounting option
  • Remote mount option includes mounting plate and transformer

Electrical:

  • Powered from panel transformer (remote option powered by 24VAC transformer)
  • 200mA @ 24VDC maximum draw per module

Operating Environment:

  • Location: Interior space
  • Operating Temperature: 0° to 50° C
  • Humidity: 10% - 90% Non-condensing
  • Atmosphere: Non-explosive/corrosive
  • Vibration: Stationary

Certifications and Approvals:

  • FCC Part 15