LightLEEDer Retrofit Insert (GE compatible)
A LightLEEDer Retrofit Insert-12 -24 -32 -40 -48 can take your present outdated or failing lighting control system and get it up to today's standards. The retrofit is compatible with lighting panels manufactured by GE. All of the enhanced features of the LightLEEDer system will be available with this retrofit system from LightSync switches to BAS control. Upgrades are as simple as removing the existing hardware and replacing it with the LightLEEDer hardware provided on a single back plate insert. Reuse existing enclosure, conduit, and wiring. The LightLEEDer programmable lighting controller retrofit insert provides a dependable, flexible, and energy savings controller featuring the robust Reliant40 relay.
Cutsheets
Relays:
- Superior latching relays
- Switch type override control
- 40 Amps @ 120, 277, 347 VAC
- SCCR to 18,000 symmetrical amps
- 1 pole configuration
Safeguards:
- Power surge and spike suppression up to 123 volts on the 24VAC power input
- Data line surge and spike suppression up to 8kv direct and 15kv thru air
- Memory retention for firmware and programming up to 200 years and electrostatic discharge to 4kv
- Real-Time-Clock time retention 45 days or greater without power
- Internal memory backup and restore
Physical:
- 12 Relay Insert: 13.09"H x 15.05"W x 4.25"D (No Door provided)
- 24 Relay Insert: 17.25"H x 15.04"W x 4.25"D (22.5" H x 24" W Door Included)
- 32 Relay Insert: 20.18"H x 15.04"W x 4.25"D (22.5" H x 24" W Door Included)
- 40 Relay Insert: 28.18"H x 15.04"W x 4.25"D (36" H x 24" W Door Included)
- 48 Relay Insert: 28.18"H x 15.04"W x 4.25"D (36" H x 24" W Door Included)
- Double sided construction similar to GE
- Provided with pre-drilled mounting holes
- High voltage barriers separate Normal/Emergency/Class2 wiring
- NOTE: If door size is not listed contact ILC
Electrical:
- 120/277 VAC @ 1 amps or optional 347 VAC
Capacities:
- Up to 12, 24, 32, 40, or 48 single pole relays
- 1 to 4 add-on modules
Operating Environment:
- Location: Interior space
- Operating Temperature: 0° to 50° C
- Humidity: 10% - 90% Non-condensing
- Atmosphere: Non-explosive/corrosive
- Vibration: Stationary
Certifications and Approvals:
- UL and CUL listed
- FCC Part 15
- Title 24
- ASHRAE compliant
- LEED compliant
Technical Bulletins
- Made in the USA
- Digital CAT-5 Ready
- Electronics, Relays and Transformer provided on a single insert
- Door Included for 24, 32, 40 and 48 size enclosures
- Installs directly in an existing GE enclosure
- Conduit and wiring can be reused
- Capacity of up to 48 relays
- Relays are the superior Reliant40 design
- Addressable relay driver boards provided as standard for Left/Right sequencing
- Optional non-addressable relay driver boards for Odd/Even sequencing
- Optional inputs for switches and occupancy sensors
- Supports LightSync data line devices
- Standalone or networked controls
- Networked with CAT5 cable
- BAS/EMS interface options
- Compatible with standard LightLEEDer panels
- Same features as the LightLEEDer controller
- Meets current energy code