LightLEEDer Programmable Lighting Control LightLEEDer Programmable Lighting Control
LightLEEDer Lighting Control Panel LightLEEDer Lighting Control Panel

LightLEEDer Programmable Lighting Control

Models: LL04, LL08, LL16, LL24, LL32, LL40, LL48, LL56, LL64

The LightLEEDer programmable lighting control relay panel is the key to a powerful, dependable, flexible and energy efficient lighting system. LightLEEDer panels come with our new Reliant40 relays which feature a superior four contact design—the first true 40Amp lighting relay. Reliant40 relays come in 1-, 2- and 3-pole configurations in a robust breaker-style body. LightLEEDer panels range in size from 4 to 64 relay capacity and are equipped with CAT-5 RJ45 connectors for LightSync data line devices and interconnecting panels. Panels include a keyboard and LCD screen, along with USB and TCP/IP connections for easy programming with our free LightLEEDer Pro Software. Add-on modules are available for connecting to BAS, theatrical, or security systems.

Cutsheets

LightLEEDer Relay Panel

Installation Guides

LightLEEDer 8-64 Panel (ID0015)

LightLEEDer Controller Installation/Replacement (ID0013)

LightLEEDer Panel Node Address (ID0012)

LightLEEDer Panel Installation Document

LightLEEDer TCP/IP Settings

LightLEEDer Advance Network Controller (ID0014)

LightLEEDer Relay Driver Module (ID1014)

LightLEEDer Reliant R40 Relay (ID0206)

LightLEEDer Panel Node Address (ID0012 Rev. B)

LightLEEDer High Voltage Divider and Barrier (ID0023)

Specifications

Relays:

  • Superior breaker style design
  • Switch type override control
  • Lockout feature disables control from panel
  • 40 Amps @ 120, 277 and 347 VAC, 1-pole
  • 40 Amps @ 208/240/480, 2 & 3-pole
  • R40 Relays ordered separately

Safeguards:

  • Power surge and spike suppression up to 123 volts on the 24VAC power input
  • Data Line surge and spike suppression up to 8Kv and 15Kv through air
  • Memory retention for firmware and programming up to 200 years and electrostatic discharge to 4Kv
  • Real-Time-Clock time retention 45 days or greater without power
  • Internal memory backup and restore

Physical:

  • Double-sided construction for mounting directly to breaker box or stand alone
  • Pre-drilled mounting holes for easy installation
  • Provided with a removable hinged locking door. 4 size enclosure provided with a screw cover.
  • High voltage barriers separate Normal/Emergency and Class 1/Class 2 wiring
  • Optional NEMA 4 and 4X enclosures available

Electrical:

  • 120 or 277 VAC @ 1 Amp, 347 VAC optional

Capacities:

  • Up to 64 single pole relays
  • 2 to 4 add-on modules

Operating Environment:

  • Location: Interior space
  • Operating Temp.: 0° to 50° C
  • Humidity: 10% - 90% Non-condensing
  • Atmosphere: Non-explosive/corrosive
  • Vibration: Stationary

Certifications and Approvals:

  • UL
  • CUL
  • FCC Part 15
  • FCC Part 68
  • Title 24
  • ASHRAE compliant
Resources

User Manuals

LightLEEDer Operation Manual

LightLEEDer Quick Installation Guide

LightLEEDer Quick Reference Guide

Video Training

LightLEEDer Training - Configuring a LightSync Photo Sensor

LightLEEDer Training - Setting a Timer

LightLEEDer Training - Setting the Clock

LightLEEDer Training - Uploading and Downloading using LightLEEDer Pro Software

LightLEEDer Training -Checking Status and Control

Technical Bulletins

LightLEEDer TCP/IP Configuration (TB0003)

LightLEEDer-4 Controller Jumper Setting Detail (TB0010)

LightLEEDer Firmware Up-Date (TB0016)

UL 924 Lighting Control With 0-10V Dimming (TB0017)

Vivarium Lighting Sequence of Operations (TB1600)

LightLEEDer Fire Alarm Override Programming (TB0020)

Input - Output Device Addressing (TB1800)

ILC Compliance for Title 24 - 2019 Demand Response (TB1605)

LightLEEDer Panel Capacity Worksheet (TB0026)

Specifications

LightLEEDer Specification

Product Details

LightLEEDer 4-64 Panel Enclosure Dimensions (PD0016)

LightLEEDer Accessories Quick View

LightLEEDer Controller (PD0018)

Brochures

LightLEEDer Brochure

Features
  • Made in the USA
  • Digital CAT 5 ready
  • Automatic receptacle plug load and lighting circuit control
  • Programming Options are done with a Integrated keypad with 4-line LCD display or using LightLEEDer Pro software via USB or TCP/IP.
  • Network Capability allows you to connect up to 254 panels and 64 LightSync devices per panel, plus an additional 254 devices on the panel network.
  • Internet Capability to interconnect panels across the internet.
  • Relay Groups can comprise any relay on the network and be assigned to any of the 256 available groups — controlled by any timer, switch, or other external commands.
  • Relay Presets can be programmed from any relay ON/OFF patterns and be assigned to any of the 256 available presets —controlled by any timer, switch, or other external commands.
  • Timer Scheduling for 128 available timers that can turn relays ON or OFF for Time-of-Day, Astronomical times, and Open/Close.
  • Clock Functions include Automatic Astronomical calculation of Sunrise and Sunset, Adjustable Daylight Saving Time and Enable/Disable.
  • Switching Inputs accepts virtually any type of switch, momentary or maintained, 2- or 3-wire switch and directly powers motion sensors, data line switches and devices.
  • Switch Input Flexibility is provided with time-of-day function change and also has “and/or” logic built in.
  • Add-On Modules available for each controller, and include BACnet IP, BACnet MSTP, Modbus RTU, Modbus ASCII, N2, LonWorks, DMX512, DTMF telephone switching and modem.